Gold Member Since 2014
Audited Supplier
Quanzhou Koqi Electronic Co., Ltd.

Emergency Call System, Nursing Call System, Wireless Nurse Calling System manufacturer / supplier in China, offering Most Popular Transmitter Pagers 200CD+K-300+K-W-2-H for Hospital Patient Nurse Call System, CE Approved Restaurant Hotel Service 433.92MHz Customer Waiting System, Hotel Sell Wireless Calling Pager K-4-C+Y-650+K-M Number Paging System and so on.

(/ )

Supplier Homepage Product Wireless Calling System Hospital calling system Most Popular Transmitter Pagers 200CD+K-300+K-W-2-H for Hospital Patient Nurse Call System

Most Popular Transmitter Pagers 200CD+K-300+K-W-2-H for Hospital Patient Nurse Call System

FOB Price: Get Latest Price
Min. Order: 1 Set
Production Capacity: 100PCS/Week
Transport Package: Each Unit Be Packed in Standard Box
Payment Terms: T/T, Paypal, Money Gram, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: K-200CD+300+K-W2-H
  • Call Type: Mixed
  • Certification: CE
  • Name: Patient Nurse Call System
  • Display Size: 225*165*40mm
  • Display: Show Room Number and Bed Number
  • Frequency: 433.92MHz
  • Warranty: One Year
  • Trademark: KOQI
  • Origin: Fujian, China
  • Usage: Commercial
  • Hardware Technology: All-in-One
  • Condition: New
  • Range: 300m
  • Application: Restaurant Hotel Hospital Coffee Shop
  • Digit: 3 Digits Number
  • Working Voltage: DC9V
  • Button Key: Call Button From Cord; Call Button; Cancel
  • Specification: CE
Product Description
Most Popular Transmitter Pagers 200CD+K-300+K-W-2-H For Hospital Patient Nurse Call System

1. Patient Nurse Call System
Patient Nurse Call System is widely used in the service area. It consist of room's bed button for patient use and signal receiver for nurse/doctoruse. When a patient need any service, he or she just press the button near to him or her, then his or her room's bed number will be shown on the display for nurse's attention.

2. Please be kindly noted as follows:
1) A complete system should consist of transmitter and signal receiver, the two parts have to work together.
2) The package size and total weight should be subject the final quantity you ordered.


3. Specification:

Specification of display receiver K-200CD:
1. With high strength ABS material cover
2. Use digital code technology and the function is steady and reliable.
3. Show 3-digit number and also can show ABCDHLPU, easy to distinguish the service area. from 001-999, A01-U99.
4. Can work with 200pcs 1-key or multi-kesy call buttons in max
5. Can show different service type by fixed, slow flash, flash
6. Can save 10 calling information in turn, and apply in basic service places.
7. Calling Alert: sounds or music.
Technical parameters:
Working voltage: DC12V~18V 
Working current: <20mA 
Working Frequency: 433.92mhz
Dimension: 225*165*40mm
Most Popular Transmitter Pagers 200CD+K-300+K-W-2-H for Hospital Patient Nurse Call System
Specification of Wirst apger K-300:
1. It can work with 99pcs 1-key and multi-key transmitter in max
2. Showing 4-digit number from 0001-9999 and first letter can be A B C D E F H I J L M N P R T U W Y
3. Can indicate different service type via last letter
4. Can show total number of coming calling.
5. Can store 10 calls and track the calls up and down.
6. Showing current time when stand-by.
7.2 reminder ways: Sound prompt or vibration.
8. Battery type AAA 1.5v
9. Battery stand-by time is 45days
10. Build an comfortable environment for customers
11. Technical parameters:
*Power: AAA LR03 #7 battery, 1.5V
*Working Frequency: 433.92MHz
*Transmitted Distance>300m in open area
*Dimension: 55*45*18mm


Specification of K-W2-H call button
1.Work with our receiver to combined the wireless calling system
2.Can be installed on wall-mounted installation.
3.When the customers or patients need help only push cord to call, the calling number will be shown on the screen, so everyone can easy to know who is calling.
4.3-key:Call button from cord;Call button and cancel button
5.Color:White
6.Material:PC
Technical Parameter:
Working voltage:DC12V
Working current:≤35mA
Use Frequency:433.92mhz
Transmitted Power:≤10mW
Transmitted Distance>300m in open area
Dimension:80*80*10mm
Any language any LOGO acceptable
Most Popular Transmitter Pagers 200CD+K-300+K-W-2-H for Hospital Patient Nurse Call System
4. Shipping information:
DHL, EMS, FedEx, UPS, Post airmail door to door service, 5-7 days from China to your country.

5. Warranty: One year

6. FAQ
Applications
Wireless calling system can be used in restaurants, hotels, hospitals, tea house, coffee shops, health clubs, beauty salon, SPA center, bars, swimming pool, beach, etc

What are the components of the wireless calling system?
1. Wireless receiver, installed on the count
2. Call button, installed on each table
3. Signal repeater (optional), enhance the signal

How does the system works?
1. After your customer gets seated the waiter informs them that when they require service, all they need to do is press the button sitting on their table.
2. When the customer presses the call button on their table, their table number will appear on the reciever with ringing. Waiters then head over to the table and provide service to the customer promptly and quickly.

Most Popular Transmitter Pagers 200CD+K-300+K-W-2-H for Hospital Patient Nurse Call System
If you are interested in it, please contact me in any time, i will reply you within 24 hours. Thank you. 

Send your message to this supplier
Avatar
Miss Alice
salesman
*From:
To: Miss Alice
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now